| 加入桌面 | 手机版
免费发布信息网站
贸易服务免费平台
 
 
发布信息当前位置: 首页 » 供应 » 手机通讯 » 通信线缆 » 橙色光纤槽道

橙色光纤槽道

点击图片查看原图
品 牌: 乾华 
型 号: FRW 
规 格: FRW 
单 价: 面议 
起 订:  
供货总量: 1000000 米
发货期限: 自买家付款之日起 天内发货
所在地: 江苏 苏州市
有效期至: 长期有效
更新日期: 2014-07-13 20:24
浏览次数: 509
询价
公司基本资料信息
 
 
 
【橙色光纤槽道】详细说明
规格:橙色材质:工程塑料合金工艺:注塑/注射适用范围:通信机房特点characteristic采用工程塑料阻燃ABS,表面光滑,使光纤自然平铺,走线规则有序;采用封闭式槽道,重量轻,具有较高的冲击韧性和良好的机械性能,保护光纤不受损伤;出口位置灵活,能满足各种地方出纤的需要,出纤口波纹管保护光纤;三通、四通接头,及各种弯头,满足各种走线需求,灵活配置;标准化模块设计,安装方便,结构紧凑,槽道连接可靠,可以上固定,也可下固定;走线架和走线槽道整体设计,布局合理,外形统一,美观整齐。Closed raceway protects optical fiber,made inanti-flamingengineering plastic with light weight, high impact toughness and good mechanical properties. It can be mounted easily with T joint, cross joint, various elbows, flexible exit and corrugated pipe, etc.主要技术指标main parameters1工作温度thermal rating: 5℃~ 45℃;2相对湿度relative humidity:不大于85%( 40℃);3大气压力atmospheric pressure:70kPa-106kPa;4光纤槽道色泽均匀,表面平整、光滑、洁净、无飞边、暗泡、收缩、凹陷或机械损伤等缺陷;Even color, smooth and clean. without flash, dark bubble, shrinkage, depression or mechanical damage, and other defects.5光纤槽道在恒定温热试验前、后,其内外表面之间能承受交流4200V(方根值)工频正弦波电压持续1min的介电性能试验。试验后绝缘电阻不小于20M ;Dielectric performance test is done before and after constant temperature test, the communication 4200V (rad value) industrial frequency sine wave voltage is applied between internal and external surfaces for 1minute. After test insulation resistance is no less than20M .,6光纤槽道能承受低温试验。试验后,试样不产生裂痕或脆断;After low temperature test,thesampledoes not appearbreaks or brittle fracture7光纤槽道能承受规定条件下的老化、冲击试验。试验后,试样不产生裂纹或脆断;After the stated conditions of aging, impact test,thesampledoesn tcrack or brittle fracture,8塑料件燃烧性能:Plastic combustion performance⑴注塑件、挤出件制品燃烧性能符合等级:GB/T2048-1996中FV-0级;Plastic injector, extruder products combustion performance accords with levelFV-0 of GB/T2048-1996.⑵波纹软管制品燃烧性能符合等级:GB/T2048-1996中FV-2级。Corrugated pipe combustion performance accordsto level ofFV-2 of GB/T2048-1996.订货指南Order guide测绘surveying and mapping测量待装机房光纤传输设备的位置Measuring the position of optical equipment,根据光纤设备的位置和数量以及走线架的高度和间距,确定出口的形式和数量The form and quantity of exits is determined by the position and number of optical equipments and the height and spacing of wiring rack.根据光纤槽道的路径,确定零部件的数量The number of all sorts of parts is determined by the path of optical fiber raceway.根据走线架,确定支撑件Supports is determined by wiring rack与客户沟通Communication with customer确定光纤槽道的路径Determinethe path of optical fiber raceway.确定将来是否扩容Determine if expansion in the future现场勘测,确定方案,给出配置并报价Field investigation, determine the scheme, configuration and quotation
0条 [查看全部]  【橙色光纤槽道】相关评论
 
更多..本企业其它产品
 
更多..推荐产品

[ 供应搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]

 
站内信(0)     新对话(0)